LIGGGHTS® - User Forum

LIGGGHTS® related topics can be discussed here: discussion about models, installation, feature requests and general discussion

Read_data for bonded particle model

Submitted by PerB on Wed, 04/15/2020 - 11:46

Hi!

Im having trouble with read_data for a model with bonded particles (Schramm/Richti83) using adhesive particles (washino/capillary/viscous).

I cant seem to get the format right in the data-file. Is there a way to check what format my particles have (e.g. ID x y z ...) When I use write_data to create a file I get the following format:

Atoms

1 1 9.0780778811098348e-03 8.4565641784780238e-03 1.9864876941739838e-03 1.8000000000000000e-05 1.0000000000008616e+03 0 0 0

LIGGGHTS youngsModulus limitation for CGS units is not consistent with SI units

Min Zhang's picture
Submitted by Min Zhang on Tue, 04/14/2020 - 00:34

Hello all,

I am using LIGGGHTS version 3.6.0 and CGS units. I am getting this error:
ERROR: youngsModulus <= 1e8 required for CGS units

So I think the unit here is dyn.cm−2 (=0.1 Pa), which means the limitation here is 1e7Pa. Am I understanding it correctly?
If it is yes, then it is not consistent with the youngsModulus limitation in SI units (1e9Pa). So I am wondering why?

Thanks!

Tube filter is giving opposite scaling

Submitted by Sounik on Sun, 04/12/2020 - 08:23

Hi everybody,

I am showing the force chains of a granular assembly obtained from LIGGGHTS using Paraview.
Problem1: Scaling is occurring in the reverse order, i.e. the weaker force chains are thicker and the strong force chains are thinner.
Problem2: Horizontal lines can be seen joining the lateral boundaries.

PS: I am using periodic boundaries at the lateral boundaries

Any suggestions will be very helpful.

Thanks,
Sounik

Different forces from particles dump and computed from contacts dump

Submitted by iluvatar on Thu, 04/09/2020 - 23:41

Hello,
I need to compute some parameter that relates the forces on particles to the force on contacts. I assumed that if particle i have n contacts, by adding up the forces at each contact I will recover the total force on the particle (without external forces). Unfortunately, that does not seem to be the case.

How to insert initial positions for multispheres?

Submitted by Andrea Mellado on Mon, 04/06/2020 - 17:10

Hi,

I would like to know if it is possible to define the initial position of a multisphere in LIGGGHTS (eg. placing a cube in the bottom of a tank) instead of inserting it at random places in a domain?
Also, in the "multisphere_stone_restitution" example, I did not understand how the atoms' positions were defined: in the "stone1.multisphere" file, the x, y, z coordinates are all positives, but when I output the results in Paraview, the x and y coordinates are negative. How are the atoms' positions actually defined?

Thank you for your time,
Andrea M.

Simulation slowering

Submitted by AzamatSalamat on Sat, 04/04/2020 - 12:25

Hello!

I am a new user to LIGGGHTS and I have been doing a research related to the centrifugal compaction of metal powder particles. I have set a simulation which is taking quite a long time on my laptop.
I have set the thermo command to show the status each 10000 steps (there are 8E7 steps in total). I have noticed that while in the beginning after 1 hour 1 million steps have been completed now the simulation is much slower and now in 1 hour there are about 300 000 steps completed.