compute pressure & compute temp vs. compute stress/atom & compute reduce
Hi,
I need the average pressure between the particles. I tried two ways with exact the same results. compute pressure for all atoms using the temperature from a compute temp and compute stress/atom for every single particle and sum these with compute reduce. What would be faster? Is there a difference in speed between compute reduce sum and the variable sum() command?
Regards,