Error tutorial

Submitted by rkromer on Tue, 07/11/2017 - 14:31

Hi,

I have this message when I run the tutorial model after installing:

mar. 11. juil. 14:20:50 2017
Check simulation settings started

File found: C:\Users\robin.kromer\Desktop\Starter_chute\Simulation_1\in.liggghts.chkdem

Please wait...

ERROR: Error reported: failed to launch ' -in C:\Users\robin.kromer\Desktop\Starter_chute\Simulation_1\in.liggghts.chkdem -thermo result_monitor.txt -wb' on IPF4040

Error (3) Le chemin d’accès spécifié est introuvable.

Check settings terminated with warnings/errors.

Can you tell me why it does not work ?

Regards

Robin KROMER

alice's picture

alice | Wed, 07/12/2017 - 12:41

Hello Robin,
the error message seems to indicate, that the liggghts executable has not been found. Could you please have a look at the install_result.log file (this is inside your CFDEMworkbench folder. You should find the comment "Command executed correctly!" three times (LIGGGHTS, MPI and LIGGGHTS-MPI). Is this the case?
If yes, please go to File/Options and check, if the path to the liggghts executable (liggghts.exe located in your CFDEMworkbench-xxx/LIGGGHTS-Workbench/bin) is correct.
Cheers,
Alice