Modelling Repeated Load Triaxial Test.

Submitted by rsharma on
Attachment Size
Actual Loading Regime 23.39 KB
top_wall_stress.png 37.87 KB
input.txt 15.1 KB
Sherif

I'm new in liggghts and I want to start making a triaxial test. I really appreciate if you can send me this project to start with (restart, stl files, etc).
Thanks in advance

Email: Sherif.atif.bdr@cu.edu.eg

Tue, 20 Apr 2021 - 21:47 Permalink

I have been trying to model repeated load triaxial test. It's a stress-controlled test. I was able to match the loading curve but during unloading force is suddenly dropping to lowest levels. I experimented with different kp values for top servo wall and defining several unloading target levels but I did not get desirable result.
I am attaching some of the pictures for reference. Please let me know if I can do something to achieve the proper result.