Simple question about YoungsModulus...

Submitted by hbc on
aaigner

Hi hbc,

If you use
units si
Yes, it is Pascal, but in DEM simulation the Young's modulus is usually artificially reduced to reduce the required timestep.

In your case, most probably the time step is too big, thus the resulting forces are very large.

Bests
Andreas

Fri, 23 Oct 2015 - 10:22 Permalink
Daniel Queteschiner

You can, for example, estimate the required time step size in the LIGGGHTS script, by using the following formula
variable youngsModulus equal 5.0e6
variable poissonsRatio equal 0.45
variable radius equal 0.005
variable density equal 2000
variable shear_mod equal ${youngsModulus}/(2.0*(${poissonsRatio}+1.0))
variable t_rayleigh equal PI*${radius}*sqrt(${density}/${shear_mod})/(0.1631*${poissonsRatio}+0.8766)
variable dt equal 10.0^(floor(log(${t_rayleigh}))-1)

Fri, 23 Oct 2015 - 13:51 Permalink
esmaeilyazdani

Dear All

when I change artificially young modulus to reduce time step, is my simulation valid yet? I think this matter can affect my results.

Regards

Esmaeil

Tue, 27 Oct 2015 - 19:02 Permalink
ckloss

Hi Esmaeil,

yes you are right. Typically most people would use 5e7 Pa as Young's Modulus, but this will of course effect the physics - e.g. wave propagation speed will be different

Best wishes
Christoph

Thu, 10 Dec 2015 - 22:22 Permalink

Hi, I'm running the simulation of steel particle sedimentation.
In the input file of LIGGGHTS, I think that the unit of 'YoungsModulus' is [Pa] in SI unit.
But, when I write the steel's mechanical property(about 200GPa = 200.e9) on particle and aluminium property (about 68.9GPa= 689.e8) on the wall,
the calculation results is so weird. (The particle's rebounded force is very large...)
I want to know the definite unit of YoungsModulus in the input file.
Thank you

bc