Hello Everybody,
I need to know how to couple time step between liggghts and CFD? I modified deltaT in OpenFoam but I got the error "TS is too big for coupling".
Regards,
Carlos
A project by DCS Computing and CFDEMresearch
This website uses cookies to ensure you get the best experience on our website. By continuing to browse the site you are agreeing to our use of cookies. This website uses cookies. By continuing to browse the site you are agreeing to our use of cookies. More info
Wurdon | Wed, 08/13/2014 - 11:20
Timesteps
Hi Carlos,
the coupling interval is defined in CFD/constant/couplingProperties. The DEM timestep is defined in DEM/in.liggghts_resume.
I think you have to choose the timesteps according to: CouplingInterval x DEM timestep >= CFD timestep.
Best regards,
Philipp
Carlos Guamushig | Fri, 08/15/2014 - 22:22
TIMESTEPS
Hi Philipp,
Thanks for your answer. I will try it.
Regards,
Carlos
cgoniva | Wed, 08/20/2014 - 09:44
Dear Carlos,
Dear Carlos,
I'd suggest the following procedure:
-Start with setting up the DEM part of the sim and see what DEM timestep you need there.
-then (depending on the dynamics) set the coupling interval between 1 and 500
-then set the CFD timestep accordingly
Your error message means that CFD detlaT is bigger than DEM deltaT * couplingInterval.
Cheers,