fix cfd all couple

Submitted by rfbrpr on
alice

Hello rfbrpr,
these two lines are responsible for the coupling between CFD and DEM code. "10" means that the coupling is carried out every 10 DEM-time steps.
Cheers,
Alice

Tue, 18 Sep 2012 - 16:48 Permalink
cgoniva

In reply to by anonymous_stub (not verified)

Hello rfbrpr, (nice name ;)

actually you can ignore this ten for the MPI based coupling, it has mor a "historical" than useful background!

Cheers,
Chris

Thu, 27 Sep 2012 - 15:01 Permalink
xiuhan

In reply to by anonymous_stub (not verified)

Because the coupling interval is actually defined in the CFDEM coupling properties, right? So here the definition inside Liggghts script is ignored.

Regards,
xiuhan

Fri, 13 Sep 2013 - 15:56 Permalink
cgoniva

In reply to by anonymous_stub (not verified)

exactly,

still some output is done accordingt to the statement in the in.* file

cheers,
Chris

Thu, 24 Oct 2013 - 15:09 Permalink

Hello:

I have been looking the files related to sedimentation test. And I'd like to know the meaning of this terms found in the the liggghts file.

#cfd coupling
fix cfd all couple/cfd couple_every 10 mpi
fix cfd2 all couple/cfd/force

Thanks