Forums
Hi,
I get error when I run simulation from restart file, the error message is :
......
ERROR: Could not locate a fix/property storing value(s) for coefficientRollingFriction
However, when I run simulation without MPI then it works fine (with restart).
Thanks,
Ram
can you elaborate a bit more
can you elaborate a bit more on what kind of simulation you are running and what input scripts you are using? Otherwise it's impossible to tell why this is
Christoph
In reply to by anonymous_stub (not verified)
Hi, I just poured about
Hi,
I just poured about 500000 particles in simulation box and created restart file, an then i continued the simulation with that restart file. It is working fine without mpi. I want to insert mesh after restart file. However, without mesh the error message is same. I have three types of particles in my simulation. I poured type 1 particles (with two different diameters). Type 2 would be used for mesh while type 3 is for wall.
The material properties:
fix m1 all property/global youngsModulus peratomtype 2.0e6 2.0e6 2.0e6
fix m2 all property/global poissonsRatio peratomtype 0.45 0.45 0.45
fix m3 all property/global coefficientRestitution peratomtypepair 3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
fix m4 all property/global coefficientFriction peratomtypepair 3 0.1 0.27 0 0.27 0.27 0 0 0 0
And, i used walls as:
fix xwalls all wall/gran/hertz/history 1 0 xplane 0 0.25 3
fix ywalls all wall/gran/hertz/history 1 0 yplane 0 0.25 3
fix zwalls all wall/gran/hertz/history 1 0 zplane 0.0 NULL 3
Thanks,
Ram
In reply to by anonymous_stub (not verified)
mesh after restart
Hi,
Is it not possible to insert mesh after restart file? I did it but it is not dumping any force/stress to mesh.
Thanks,
Ram
In reply to by anonymous_stub (not verified)
Hi Ram, Do you want to insert
Hi Ram,
Do you want to insert mesh like .stl?
I inserted .stl after particles setting in my simulation to move it inside particles (with restart).
If I run the movecad directly it seem like the particles are "ghosts" and the .stl doesn't interact with them.
If I run first a "empty" run inserting the .stl only (just few iterations) and then (from the new restart) moving the cad the simulation is ok.
I suggest you to run first to read the .stl and then to move it
Regards
Andrea
In reply to by anonymous_stub (not verified)
Hi Andrea! Thanks for help, I
Hi Andrea!
Thanks for help, I will try this. But I can not run restart file with mpi, it stuck with following message:
ERROR: Could not locate a fix/property storing value(s) for coefficientRollingFriction
Thanks,
Ram
In reply to by anonymous_stub (not verified)
Hi Ram, I can't help you
Hi Ram,
I can't help you about "coefficientRollingFriction".
Have you defined it as "property/global"? Have you defined it also in in. file where you read the restart?
Regards
Andrea
In reply to by anonymous_stub (not verified)
Hi Ram,
Hi Ram, are you using the rolling friction model in a pair style?
Christoph
In reply to by anonymous_stub (not verified)
Dear Christoph, No, I haven't
Dear Christoph,
No, I haven't define this model in my pair style.
Thanks,
Ram
In reply to by anonymous_stub (not verified)
can you send me your script?
can you send me your script? I would have a look then
Christoph
In reply to by anonymous_stub (not verified)
Debug of the issue
Hi,
I debugged the problem. We don't need to comment the following line (only with new version, old versions are valid for both options):
pair_style gran/hertz/history 1 0 #Hertzian without cohesion
This solved the problem.
Thanks...
Ram
In reply to by anonymous_stub (not verified)
So you say the comment in
So you say the comment in that line caused the problem? that would be weird though...
In reply to by anonymous_stub (not verified)
hi, i mean when i dont put
hi,
i mean when i dont write above statement in restart script (in older versions) then there is no problem, but in new version i have to write the above statement...
Best,
Ram